• Neonate Medical Air Oxygen Blender Oxygen Blender
  • Neonate Medical Air Oxygen Blender Oxygen Blender

Neonate Medical Air Oxygen Blender Oxygen Blender

Classification: Neonate Medical Air Oxygen Blender Oxygen Blender
Type: Neonate Medical Air Oxygen Blender Oxygen Blender
Certification: CE, ISO13485
Group: Human
Product: Neonate Medical Air Oxygen Blender Oxygen Blender
Transport Package: Standard Export Pack
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LTEK-BL1
Specification
1pcs/carton
Trademark
LETY
Origin
China
Production Capacity
1000units/Month

Product Description

Neonate Medical air oxygen blender oxygen blender
Neonate Medical Air Oxygen Blender Oxygen BlenderNeonate Medical Air Oxygen Blender Oxygen Blender


Specifications: 
 

Model & Specification

KY-10A

KY-10B

KY-20A

KY-20B

KY-30A

KY-30B

Concentration valve

Single

Single

Double

Flowmeter

Single

Double

Double

Humidification bottle

/

yes

/

yes

/

yes

Gas bleed valve

yes

yes

/

Main part dimension

123×63×71mm

123×68×71mm

123×68×71mm

Single/double patient use

Single patient use

Single patient use

Single/double patient use (adult)

 

Performance characteristics: 
Oxygen concentration is 21%-100% continuous adjustable 
Oxygen concentration and flow rate is adjustedseparately.  
High precision regulating and continuous steady gas output
Pneumatic control without power supply 
KY-30A and KY-30B is used for two patients simultaneously.  

 

Specification :
1,Oxygen concentration adjusting range and accuracy 
KY-10A and KY-10B:
Oxygen concentration adjusting range: 21%-100%.  
    Accuracy: ±3% O2(V/V). 
KY-20A and KY-20B: 
   Oxygen concentration adjusting range: 21%-100%.    
Accuracy: ±3% O2(V/V). 
KY-30A and KY-30B:
   Oxygen concentration adjusting range: 21%-100%. 
 Accuracy: 
  The accuracy of KY-30A and KY-30B blender is ±3% O2 (V/V)when use the single flow and the flow rate is more than 4L/min. 
The accuracy of KY-30A and KY-30B blender is ±6% O2 (V/V)when use the doubleflow and both sides flow rate are more than 4L/min 

2,Flow rate adjusting range: 
KY-10A, KY-10B, KY-30A and KY-30B:
    Flow rate adjusting range: 0L/min -18L/min.
KY-20A and KY-20B: 
    Flow rate adjusting range: 0L/min -18L/min and 0L/min-3.5L/min.
Input gas source pressure: 207kPa-517kPa. 

3,Alarm of gas source 

Gas supply pressure difference>138kPa.  
Interruption of gas supply. 
Gas supply pressure >560kPa.
The Air/Oxygen Blender is built-in pneumatic sound alarm device with the whistle sound. 
The alarm sound pressure level is>57dB(A). 
The Reverse Gas Flow of zero (The reverse gas flow from either gas inlet to the other is zero).



Neonate Medical Air Oxygen Blender Oxygen BlenderNeonate Medical Air Oxygen Blender Oxygen Blender
Neonate Medical Air Oxygen Blender Oxygen Blender

 

 

 

Neonate Medical Air Oxygen Blender Oxygen Blender
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now