• Aed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator Trainer
  • Aed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator Trainer

Aed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator Trainer

Classification: Defibrillator Trainer
Type: Defibrillator Trainer
Certification: CE, ISO13485
Product: Aed Defibrillator
Transport Package: Standard Export Pack
Specification: 100pcs/carton
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LTM-T2
Trademark
LETY
Origin
China
HS Code
9018909911
Production Capacity
1000units/Month

Product Description

Defibrillator trainer automatic external defibrillator AED Trainer for CPR training
Aed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator TrainerAed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator Trainer
Biphasic Defibrillator First Aid Automatic External Aed Defibrillator 

Aed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator Trainer
Aed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator TrainerSpecifications

Display
Screen Type: High-resolution display
Screen Size: 7 inches(17.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.

Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.

ECG Monitoring
Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles.
Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
Smart Alarms: Beeper/voice prompts indicate shockable rhythm.

Battary
Type: Rechargeable, Ni-MH battery, 12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.

SpO2 Module
Measurement Range: 30~100%, ± 2% between 80%~90%, others ± 5%
Alarm Range: User set high limit and low limit.
Alarm Accuracy: ± 10% within setting values.
Alarm time Accuracy: Less than 12 sec.

Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution, thermal print head.
Print-out Modes: Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

AED Mode
AED Function: Auto analyze and charge X3 with programmable auto energy level selection, screen prompts, and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel, press key on paddle.
Prompts: Voice and visual prompts.

Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor

 


Aed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator Trainer

 

Aed Trainer CPR Training First Aid Training Automatic External Aed Defibrillator Trainer