Customization: | Available |
---|---|
Classification: | Virus Sampling Tube |
Type: | Virus Sampling Tube |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Virus sampling kit Nasopharyngeal swab five-in-one sampling tube set, nucleic acid detection transport tube, virus sampling tube preservation solution manufacturer Nasal swab Pharyngeal swab viral transport medium Inactivated transport medium
[Product Name]Disposable Virus Sampling kit
[Packing Details]Solution 2mL/Tube,Sampling Swab.
Model No. |
Tube Size (Tolerance ±5mm) |
Swab Length (Tolerance ±5mm) |
Model No. |
Tube Size (Tolerance ±5mm) |
Swab Length (Tolerance ±5mm |
ATM-01 |
13*100mm |
150mm |
VTM-01 |
13*100mm |
150mm |
ATM-02 |
16*100mm |
150mm |
VTM-02 |
16*100mm |
150mm |
ATM-03 |
13*75mm |
150mm |
VTM-03 |
13*75mm |
150mm |
ATM-04 |
16*97mm |
150mm |
VTM-04 |
16*97mm |
150mm |
ATM-05 |
16*58mm |
150mm |
VTM-05 |
16*58mm |
150mm |
MTM-01 |
13*100mm |
150mm |
UTM-01 |
13*100mm |
150mm |
MTM-02 |
16*100mm |
150mm |
UTM-02 |
16*100mm |
150mm |
MTM-03 |
13*75mm |
150mm |
UTM-03 |
13*75mm |
150mm |
MTM-04 |
16*97mm |
150mm |
UTM-04 |
16*97mm |
150mm |
MTM-05 |
16*58mm |
150mm |
UTM-05 |
16*58mm |
150mm |
[Intended use ]
This product is to collect virus detection samples from throat or nasal secretions, and the swab samples will be kept in culture medium, which can be used for virus detection, culture and isolation.
[Main composition]
The product mainly consists of sample tube, cap, solution and swab
[Storage Conditions and validity]
Store at 2-25 °C, and it can be used until the expiry date on the label. The culture solution can also be stored separately at -20ºC. If stored at -20ºC, please unfreeze it at 2-8ºC before use. Transportation under room temperature no more than 96 hours of after sampling
[Sample Requirements]
1, Sample can be taken from throat and nose with the swab
2, Samples can be stored at room temperature for 7 days if not arrange nucleic acid extraction and purification immediately after collection
3, The collected samples should be stored in the sample preservation solution. If not tested immediately, they can be stored at room temperature or refrigerated or frozen, but repeated freeze-thaw should be avoided
4, Sampling swabs must not be placed in the sample preservation solution before use; they should immediately be placed in the preservation tube containing the sample preservation solution after sampling. Break the swab near the top, and then tighten the tube cover. It should be sealed in a plastic bag or other packaging container, stored at a specified temperature and submitted for inspection.
[Instructions]
1. Take out the sampling tube and swab. Before sampling, mark therelevant sample information on the label of the preservation tube or attach the bar code label.
2.Take out the sample swab (if the sample swab is packaged independently, please tear it off from the easily torn mouth at the end of the packaging bag) and sample with the sample swab at the corresponding part according to different sampling requirements. A) throat sampling: first press the tongue with a tongue spatula, then extend the head of the sampling swab into the throat and wipe the bilateral pharyngeal tonsils and the posterior pharyngeal wall, and gently rotate to fully sample. B) nasal cavity sampling: Measure the distance from the tip of the nose to the earlobe with a swab and mark it with your finger. Insert the swab into the nasal cavity in the direction of the nose (face), The swab should be extended at least half the length from the earlobe to the tip of the nose. put the swab in the nose for 15-30 seconds. Gently rotate the swab 3-5 times to take out the swab.
3. Place the swab into the storage tube immediately after sampling, break off the sample swab, dip the head of the swab in the preservation solution, discard the sampling handle and tighten the cap.
4. Freshly collected samples should be transported to the laboratory within 48 hours. If used for viral nucleic acid detection, nucleic acid should be extracted and purified as soon as possible. If it cannot be sent to the laboratory within 48 hours, it can be stored at room temperature for 7 days. If long-term storage is needed, it should be stored at -40~-70ºC (the stable storage time and conditions should be verified by each laboratory according to the final experimental purpose).
5. In order to improve the detection rate and increase the viral load of the collected samples, samples from throat and nose with swab can be collected simultaneously and put into a sampling tube for examination.
Product Performance Index
Model No. |
PH Value |
Model No |
PH Value |
ATM-01 |
7.2±0.2 |
VTM-01 |
7.4±0.2 |
ATM-02 |
VTM-02 |
||
ATM-03 |
VTM-03 |
||
ATM-04 |
VTM-04 |
||
ATM-05 |
VTM-05 |
||
MTM-01 |
6.8±0.2 |
UTM-01 |
7.3±0.2 |
MTM-02 |
UTM-02 |
||
MTM-03 |
UTM-03 |
||
MTM-04 |
UTM-04 |
||
MTM-05 |
UTM-05 |
Delivery detail:
UPS/DHL/FEDEX/TNT express are available for your choose which take 3~ 5 days to
arrive,and we will offer the tracking number for you to check the status of your items
online at any time.
By air cargo which takes about one week to arrive .
By sea which takes about 20-30days to arrive , depending on your actual requirements.
Delivery detail:
UPS/DHL/FEDEX/TNT express are available for your choose which take 3~ 5 days to
arrive,and we will offer the tracking number for you to check the status of your items
online at any time.
By air cargo which takes about one week to arrive .
By sea which takes about 20-30days to arrive , depending on your actual requirements.
Our Services
1.Warranty:
12 months warranty for product.
If any technical problem during warranty time, replacement parts will be sent free of charge.
Technical support is also available in whole time.
2.Our Advantage
1. Reply your enquiry in 24 working hours.
2. Experienced staffs answer all your questions in fluent English.
3. OEM is available if the quantity is large.
4. We offer very competitive for all our products.
3.After-sales
Our machines undergo an extensive and strict testing and quality control procedure, ensuring every item purchased meet global quality standards.It's safe and reliable quality for all our products.