• ESR System ESR Rack ESR Fast Detector ESR
  • ESR System ESR Rack ESR Fast Detector ESR

ESR System ESR Rack ESR Fast Detector ESR

Type: ESR Fast Detector
Material: Plastic
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: 5 Years
Group: Hospital
Logo Printing: With Logo Printing
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LTL-KJ823
Product Name
ESR Fast Detector
Transport Package
Standard Export Packimg
Specification
200pcs/carton
Trademark
LETY
Origin
China
Production Capacity
100000units/Day

Product Description

ESR Rack
Model: LTL-
KJ823ESR System ESR Rack ESR Fast Detector ESR

Specifications

REF. Original REF. Specification Qty in case Detailed information
179-0014 KJ822 10-Position 20 ESR Rack

 

Product Overview

 

Main Features:

Better compatibility compared with Westergren method.

A safe, reliable and airtight operation during the whole process from blood collection to test, free of biological contamination.

Designed with spirit level of patent technology, which ensures the detector horizontal and aclinic.

10 channels, synchronous operation allowed.

Only 30 minutes needed for reading, easy and fast.

Stainless steel soleplate with silicagel cushion on, which will avoid any noise or breakage when the ESR tube being placed.

How to Use:

Carry out the venous blood collection according to standard requirements with 9x120mm ESR vacuum tube.

Immediately invert the tube at 180 degrees for 6-8 times to achieve thorough mixing, which will avoid hemolysis, clotting or blood bubble.

At the room temperature of around 20ºC,vertically place the ESR tube containing blood sample onto the detector, note down the starting

time and relevant numbers. Keep the detector still for 30 minutes and then read the millimeter of erythrocyte sedimentation.

Detailed reading method: Keep it stable for 30min, align the plasma concave in ESR tubes to the zero scare of the detector. Then, read the

data by aligning the upper surface of erythrocyte to the scale on the detector. (See as the schematic diagram)

Notice:

Before operation, the ESR fast detector should be put on a steady platform and adjusted to be horizontal with knobs below the soleplate.

The ESR tubes should be kept vertical during the whole sedimentation process, angle of inclination should not be more than 3°. Orelse, the

testing result will be of large deviation.

Keep the room temperature at 20±5ºC, sedimentation time 30±2min.